Communication Protocol
CubiScan 25 Command Set
CubiScan 25 Service Manual
6 4
Key Coordinates
This command causes the CubiScan 25 to accept keyboard input in touch pad coordinates. The X
coordinate is horizontal, the Y coordinate is vertical.
Location Identification
This command is used to set the CubiScan 25 location identification. The location identification
is a six-digit code which uniquely identifies the CubiScan 25 within the user’s operation. This
location identification is included in each measurement packet. This data is stored in permanent
memory and need only be set once for each CubiScan 25.
Pos Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Key Command
Alpha
(k)
6Bh
3
4
X Coordinate
Numeric
0000-9999
7
1
Comma
Alpha
(,)
2Ch
8
4
Y Coordinate
Numeric
0000-9999
12
1
End of Text
Control
(ETX)
03h
13
1
Carriage Return
Control
(CR)
0Dh
14
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Key Command
Alpha
(k)
6Bh
3
1
Acknowledge
Alpha
(A)
41h
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Negative Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Key Command
Alpha
(k)
6Bh
3
1
Neg. Acknowledge
Alpha
(N)
4Eh
4
1
End of Text
Control
(ETX)
03h
5
1
Carriage Return
Control
(CR)
0Dh
6
1
Line Feed
Control
(LF)
0Ah
Pos Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h