Communication Protocol
CubiScan 25 Command Set
CubiScan 25 Service Manual
5 6
CubiScan 100 Compatible Measure Mode
This data packet is received from the CubiScan 25 when a gate measurement is completed. It is
backwards compatible with the CubiScan 100.
Pos Len
Description
Type
Range
ASCII
Command Format
1
1
Start of Text
Control
(STX)
02h
2
1
Measure Command
Alpha
(M)
4Dh
3
1
End of Text
Control
(ETX)
03h
4
1
Carriage Return
Control
(CR)
0Dh
5
1
Line Feed
Control
(LF)
0Ah
Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Measure Command
Alpha
(M)
4Dh
3
1
Acknowledge
Alpha
(A)
41h
4
1
CubiScan/Host
Originated
Alpha
(C/H)
43h or 48h
5
6
City Code
Alpha
000000-ZZZZZ
Z
11
1
Comma
Alpha
(,)
2Ch
12
1
Length Identifier
Alpha
(L)
4C
13
5
Length
Numeric
000.0-999.9
1
18
1
Comma
Alpha
(,)
2Ch
19
1
Width Identifier
Alpha
(W)
57h
20
5
Width
Numeric
000.0-999.9
1
25
1
Comma
Alpha
(,)
2Ch
26
1
Height Identifier
Alpha
(H)
48h
27
5
Height
Numeric
000.0-999.9
1
32
1
Comma
Alpha
(,)
2Ch
33
1
Dimension Unit
Alpha
(E/M)
45h or 4Dh
34
1
Comma
Alpha
(,)
2Ch
35
1
Weight Identifier
Alpha
(K)
4Bh
36
6
Weight
Numeric
000.00-999.99
1
42
1
Comma
Alpha
(,)
2Ch
43
1
Dim. Wgt. Identifier
Alpha
(D)
44h
44
6
Dim. Weight
Numeric
000.00-999.99
1
50
1
Comma
Alpha
(,)
2Ch