Part Replacement
Replacing a Load Cell
CubiScan 25 Service Manual
4 5
scale plate in place while still allowing free
movement.
17. Replace the glass platform.
18. Power the CubiScan 25 on.
19. Balance the load cells. For instructions on this
process, see
“Balancing the Load Cells” on page 23
20. Calibrate the CubiScan 25. See
for calibration instructions.
Replacing a Load Cell
This section describes how to replace a load cell.
Items Needed
•
3/32'' Allen Wrench
•
Small, Short Flathead Screwdriver
•
11/32'' Nut Driver
•
7/16'' Wrench (2)
•
1/8'' Allen Wrench
•
Replacement Load Cell
•
Zip Tie Cutters
•
Zip Ties
Complete the following steps to replace a load cell.
1. Power the CubiScan 25 off.
2. Carefully remove the glass platform and place it in a
safe location.
3. Remove the four thumb screws (two at each end of
the CubiScan 25) holding the scale plate in place.
4. Remove the scale plate and set it aside.
5. Use the 3/32'' Allen wrench to remove the eight
screws holding the load cell summing box lid in place
and remove the lid. Refer to
.
6. Locate the damaged load cell cable and disconnect
the load cell connection wires by loosening the
corresponding flathead screw with a small flathead
screwdriver. Refer to
. You only need to
Figure 62
Wires Drawing
Figure 63
Load Cell Summing Box
Figure 64
Shroud Nuts and Screws
Load Cell
Summing Box
Screws
Screws
Screws
Screws
Nuts
Shroud