CubiScan 25 Service Manual
5 0
Appendix A
Communication Protocol
This appendix contains the cable pin assignments and command set description for the interface
between the CubiScan 25 and a host computer via a serial RS-232 connection, a USB connection,
as well as for the interface between the CubiScan 25 and a network via an Ethernet TCP/IP
connection.
The
“Command Set Summary” on page 54
lists the command sets that can be used to set up the
CubiScan 25 for cubing and weighing. These command sets can also be used in the actual cubing
and weighing process.
The
“TCP/IP Command Set Summary” on page 79
lists the commands used to set up the
CubiScan 25 for TCP/IP communications with a network.
Listed below is the definable output that can be found in the “com_def.txt” file. If you want the
CubiScan 25 to check the user definable file you must enable it. To enable this function, go to
Menu > Setup (7/7)
. In the
Use COM define
field change the
N
to a
Y
.
CMNT ****** BEGIN USER DEFINITONS ********
00 STR OUTPUT_FORMAT = "HtLtWtMtVtcl"
01 UINT KB_DIM_UNITS
= "2"
02 UINT KB_WGT_UNITS
= "1"
03 UINT KB_VOL_UNITS
= "5"
04 STR LENGTH_FMT
= "%08.2f"
05 STR WIDTH_FMT
= "%08.2f"
06 STR HEIGHT_FMT
= "%08.2f"
07 STR WEIGHT_FMT
= "%08.3f"
08 STR VOLUME_FMT
= "%013.6f"
09 STR USER_DEFINED_1 = " "
10 STR USER_DEFINED_2 = " "
11 STR USER_DEFINED_3 = " "
CMNT ****** END USER DEFINITONS **********