Page
71
Dimensions
P104 Measurement Units
This parameter sets the units you want to use for programming and display
Option
Description
1 = metres
All units of measure are
METRES
2 = cm
All units of measure are
CENTIMETRES
3 = mm
All units of measure are
MILLIMETRES
4 = feet
All units of measure are
FEET
5 = inches (Default)
All units of measure are
INCHES
P105 Empty Level
This parameter is to be set to the
maximum distance
from the
face
of the
transducer to the
empty point
, in
P104
Measurement
Units
. Note this
value affects span as well, (see important information below), so should be
set before span.
Important Information
When using the
dB Mach 3
the
empty distance
is measured from
the end of the
horn
to the
empty point
in
P104 Measurement
Units
.
Important Information
When changing the Empty Distance (P105) you can also recalculate
the values for the Span so that it equals the empty distance (P105)
minus Near Blanking (P107) and the Relay Setpoints, so that they
remain at the same percentage values of the empty distance as they
were before you changed the empty distance (P105). You will be
asked the question “Recalculate Span?” if you choose yes (enter 1),
then the span will be recalculated. Any other answer will leave the
span at its original value. You will then be asked if you want to
“Recalculate Setpoints?”, if you choose yes (enter 1), then all Relay
Setpoints will be recalculated as a percentage of the new empty
distance. Any other answer will leave the setpoints at their original
values.
Summary of Contents for FlowCERT LITE
Page 1: ...FlowCERT LITE UL INSTRUCTION MANUAL...
Page 2: ......
Page 4: ......
Page 8: ......
Page 14: ...Page 6 EC DECLARATION OF CONFORMITY...
Page 18: ...Page 10 The full dimensions of the enclosure are as shown below...
Page 37: ...Page 29 This page left blank intentionally...
Page 77: ...Page 69...
Page 135: ...Page 127 This page left blank intentionally...