Page 40
Calculations
A
BSOLUTE
If the flow calculation is to be
absolute
P702
=
1
the flow will be calculated
using the formula (s) as follows:
Exponent Type
Formula
Exponent
K Factor
Suppressed
Rectangular
Weir
(Without End
Contractions)
Q=KLh
x
Where:
Q =Flow
K=
K factor
L=crest length of weir
h=head
x
=
exponent
1.50
Automatically
selected by
FlowCERT
LITE
Automatically
calculated,
dependent on
measurement,
flow and time
units chosen.
Cipolletti
(Trapezoidal)
Weir
Q=KLh
x
Where:
Q =Flow
K=
K factor
L=crest length of weir
h=head
x
=
exponent
1.50
Automatically
selected by
FlowCERT
LITE
Automatically
calculated,
dependent on
measurement,
flow and time
units chosen.
Venturi Flume
Q=Kh
x
Where:
Q =Flow
K=
K factor
h=head
x
=
exponent
1.50
Automatically
selected by
FlowCERT
LITE
Enter value of
K Factor (P718)
as required
Parshall Flume
Q=Kh
x
Where:
Q =Flow
K=
K factor
h=head
x
=
exponent
Automatically
calculated
dependent on
throat size
(P719)
Automatically
calculated,
dependent on
throat size and
measurement,
flow and time
units chosen.
Leopold Lagco
Flume
Q=KD
0.0953
h
x
Where:
Q =Flow
K=
K factor
D=pipe diameter
h=head
x
=
exponent
1.55
Automatically
selected by
FlowCERT
LITE
Automatically
calculated,
dependent on
measurement,
flow and time
units chosen.
Summary of Contents for FlowCERT LITE
Page 1: ...FlowCERT LITE UL INSTRUCTION MANUAL...
Page 2: ......
Page 4: ......
Page 8: ......
Page 14: ...Page 6 EC DECLARATION OF CONFORMITY...
Page 18: ...Page 10 The full dimensions of the enclosure are as shown below...
Page 37: ...Page 29 This page left blank intentionally...
Page 77: ...Page 69...
Page 135: ...Page 127 This page left blank intentionally...