7.2
Complete dialogue
A
main menu
for selecting the
sub-menus
, which can be used for selecting an instrument and application-dependent
number of
pages
.
Sub-menu
Page
contents
Level 1 data
The operating pages of VWERT, VPARA, VBAR, VTREND, APROG, DPROG, CONTR and
CONTR+ are shown:
display and adjustment of operating values
.
Parameter
For each function used, which has adjustable parameters a separate page is
prepared:
parameter display and adjustment
.
I/O data
There is a separate page for each used function:
Input and output data display
.
Configuration
There is a separate page for each used function, which must be configured:
configuration data display and adjustment
. For changing a configuration, the
instrument must be set to ‘offline’. (
r
operating modes
).
Miscellaneous
Page
Date, Time
:
date, time display and adjustment
.
Ü
Page
Device data
:
i
nterface, mains frequency, language display and adjustment.
Page
Online/Offline
:
online
i
offline, configuration cancelation
.
Page
Calibration
:
Display and calibration of signals to be calibrated
.
Page
Info
:
hardware, software order no., software version no. display
.
*
Page
Status CAN-BUS
:
State of eventually connected CAN-Nodes
.
Ö
Page
Status PROFIBUS
:
bus access, data communication status display
.
£
Page
Status INTERBUS
:
bus access, data communication status display
.
¤
Only with option B with built-in real-time clock
The operating version is also displayed from operating version 2
Only KS98+ (with CAN I/O extension (see page ))
Only with option B with PROFIBUS
Only with option B with INTERBUS
g
Prior to operating version 2
KS98:
was displayed additionally in the headers of main menu and five
sub-menus. Example
KS98: main menu
7.3
Selection (switch-on and operating pages)
After power supply switch-on, logo and
Main menu wait!
followed by the sub-menu during some seconds
are displayed. Unless a selection is made during this time, the first operating page entered in the sub-menu
without
marked line
is displayed. At each pressure of
I
/
D
a line (inverted display) is marked. When the page
without marked
line
is reached again by pressing keys
I
/
D
, return to the sub-menu is possible by pressing key
M
. When the
End
is
reached by pressing keys
I
/
D
, return to the main menu is possible by pressing key
M
.
Keys
I
/
D
scroll the marked line up to the menu start or down to the menu end. When pressing the key again, the
marked line jumps from the start to the end or vice versa.
Menu
9499 040 50611
Complete dialogue
22
End
..
.
D
I
D
I
M
M
M
D
I
M
D
Summary of Contents for KS 98
Page 8: ...Description 9499 040 50611 Construction 8...
Page 10: ...Important technical data 9499 040 50611 Further external in and outputs 10...
Page 12: ...Versions 9499 040 50611 I O modules for units with modular option c basic card 12...
Page 14: ...Front view 9499 040 50611 14...
Page 16: ...Mounting 9499 040 50611 16...
Page 26: ...Maintenance 9499 040 50611 Further information 26...
Page 36: ...Scaling and calculating functions 9499 040 50611 LG10 10s logarithm 36...
Page 74: ...Signal converters 9499 040 50611 MEAN mean value formation 74...
Page 128: ...KS98 I O extensions with CANopen 9499 040 50611 RM_DMS strain gauge module 128...
Page 132: ...CSEND Send mod blockno s 21 23 25 27 No 57 132...
Page 140: ...Description of KS98 CAN bus extension 9499 040 50611 140...
Page 202: ...Controller 9499 040 50611 Process value calculation 202...