Quantum and Evolution Series Installation and Operating Handbook
7-63
The carrier is on and will remain on even after the equipment is switched
off and on again.
On-mute if outage (mute if power break)
Mute on power break requires confirmation of transmission (i.e. selecting
Edit/Unit/Advanced/Operation and select `Ack Pwr Bre`) following a power
outage.
Rx enabled
When enabled, then the carrier will be switched off whenever an Rx traffic
fault is present in the modem.
RTS enabled
When RTS is enabled then the carrier is controlled by the interface RTS
line.
Factory
default:
Off
Description:
Tx
carrier
control.
Edit-Tx-Carrier-Power Screen (IF Modem)
Units:
dBm
Minimum value:
-25.0
Maximum value:
0
Step size:
0.1
Factory default:
-20.0
Description:
Tx IF output power level.
IF output power:-25 to 0dBm
[-10.0] Step 0.1dBm
New: -10.0