Quantum and Evolution Series Installation and Operating Handbook
7-136
Edit-Unit-M&C-Timeout Screen
Units:
mins
Minimum value:
1
Maximum value:
720
Step size:
1
Factory default:
5
Description:
Specifies the period of time without any user input activity after which a
user is logged out. This is true even for the local user interface (this has
an implicit login when the operator first presses a key). In Giveaway
mode, logging out causes ownership of the modem to be lost.
Edit-Unit-M&C-Interface Screen
Options:
RS232
RS485
IP – Local
Only available when IP over ESC has been selected. This pushes the serial M&C
data across to the distant end Modem via the IP ESC for use at the remote serial
ports. This link is a serial extension for control of distant end equipments.
IP – Remote
This allows the serial M&C data, received via IP from the local Modem to be used at
the distant end serial ports. Uses TCP port 6703. This link is a serial extension for
control of distant end equipments. Please refer to following pinout definition table.
Note that this mode is deprecated and
IP – Remote (Rem M&C)
should be used
Auto-logout period:1 to 720mins
[060] Step 1mins
New: 060
Remote M&C Interface:
[RS232]
New: RS232