Quantum and Evolution Series Installation and Operating Handbook
7-153
Units:
dB
Minimum value:
0.0
Maximum value:
99.0
Step size:
0.1
Factory default:
3.0
Description:
User-defined Eb/No threshold used in sun outages to mute the terrestrial
output (see previous screen).
Edit-Unit-Advanced-Operation-1 For 1 Switch To Standby Screen
Options:
Switch to standby
This option forces a modem that is on-traffic to standby. This is done by
momentarily creating a fault condition that forces a switchover to occur.
Switch to maintenance
Allows the modem to be removed from the redundancy group, therefore
preventing the unit being switched on line.
Switch to service
Allows the modem to enter a redundancy group and be available to come
on line.
Factory default:
None
Description:
Forces a switch to the standby unit and allows a modem to be removed
or added to a redundancy group.
Edit-Unit-Advanced-Operation-1 For N Screen
Menu only available if unit is an integral part of the 1:N redundancy switch. Please see
separate redundancy switch operating manual.
1-for-1: 1:Switch to standby
2:Switch to maintenance
3:Switch
to
service