Quantum and Evolution Series Installation and Operating Handbook
7-93
Edit-Rx-Demodulation-Sweep Screen
Options:
Normal
In this mode the sweep width is controlled automatically by the modem.
The width is always set to +/-32kHz by the modem.
Other
This mode allows the user to set the sweep width in order to compensate
for carrier frequency uncertainty due to Tx frequency, satellite and Rx
frequency conversions. This may be required to optimize performance at
very low data rates by setting a sweep width that is smaller than the
default.
Factory
default:
Normal
Description:
Controls the Rx signal sweep configuration.
Edit-Rx-Demodulation-Sweep Width Screen
Units:
kHz
Minimum value:
1
Maximum value:
250
Step size:
1
Factory default:
32
Description:
Controls the Rx signal sweep width when the
Sweep mode
is set to
Other
. This is a +/- setting, i.e. the total width is twice the value that is
entered. In general the default value should be use but at very low data
rates it may reduce demodulator acquisition time if the sweep width is
Sweep mode: [Normal]
1:Normal (+/-32kHz)
2:Other
Sweep width(+/-):1 to 250kHz
[032] Step 1kHz
New: 032