Quantum and Evolution Series Installation and Operating Handbook
7-28
Units:
Minimum value:
0
Maximum value:
31
Step size:
1
Factory default:
0
Description:
Controls the number of timeslots dropped off the terrestrial bearer and
sent over the satellite.
Edit-Tx-Baseband-Advanced-Timeslots-Timeslots Screen
Units:
Minimum value:
0
Maximum value:
31
Step size:
1
Factory default:
0
Description:
Controls which timeslots are dropped and in which order. Terrestrial
timeslots are mapped into the satellite frame in the order listed on this
screen, which allows timeslots to be reordered. For G.732 operation
timeslot numbers 1-32 are used, and for T1-D4 and T1-ESF, timeslot
numbers 1-24 are used. Timeslots can be entered as individual numbers
separated by commas or as an inclusive range denoted by the first and
last timeslot numbers in the range with a hyphen between them. For
example, ‘0,18-31,17,16-1’ swops timeslots groups 18 to 31 with 1 to 16
and additionally reverses timeslots 1 to 16.
Note that on this screen the
Down
arrow key is used to enter a comma
and the
Up
arrow key is used to enter a hyphen. The 0 key pressed
together at the same time as the
Right
arrow key deletes the character at
the cursor.
If the number of timeslots that are entered differ from the number
No. timeslots used:0 to 31
[01] Step 1
New: 01
Terr slots to drop to satellite
[1]
New:0,18-31,17,16-1