Quantum and Evolution Series Installation and Operating Handbook
7-146
Units:
hrs
Minimum value:
0
Maximum value:
9999
Step size:
1
Factory default:
0
Description:
Sets the threshold period for consecutive buffer slips above which a
deferred alarm is generated. A setting of 0 (zero) disables this alarm.
Edit-Unit-Advanced-Alarms-Thresholds-BUC PSU Alarm Screen
Units:
A
Minimum value:
0.1
Maximum value:
6
Step size:
0.01A
Factory default:
0.1
Description:
On L-band modems, sets the trip threshold at which a fault is declared
when the current drawn by the Tx ODU is outside the limit. Both a
minimum and a maximum current threshold can be set.
Edit-Unit-Advanced-Alarms-Thresholds-AUPC Deferred Distant AlarmScreen
DC current min:0.1 to 6A
[0.10] Step 0.01A
New: 0.10
Deferred distant E: 0.1 to 9.9dB
[0.1] Step 0.1dB
New: 0.1