Quantum and Evolution Series Installation and Operating Handbook
7-13
•
Slew
: this shows the instantaneous slew rate is the target Eb/No level set for the
remote modem.
•
Comms loss action
: this shows the action to be taken in the event that
communications with the remote modem fail – see the
Edit-Tx-Carrier-Advanced-
AUPC
section for more details of the loss action options.
Status-BUC Screen
This screen is available only on L-band modems. It is updated with the following
information:
•
Output
: this is the output power in dBm at the waveguide flange, or
Off
if the BUC is
not transmitting.
•
Mode
: in Terminal (closed loop) mode, this presents the Terminal RF output power
level (i.e. the modem output power to the BUC) and the BUC attenuation level. In
open loop mode, Terminal RF and BUC attenuation data is not shown and instead the
mode is shown as
Independent
.
•
Status
: this shows the temperature in degrees Centigrade reported by the BUC.
•
Type
: this field shows the BUC power class in Watts and the BUC current level in
Amperes.
Output: 40.0dBm
Mode: Terminal RF: -15.3dBm BUC: -10.0dB
Status: 25ºC Type: 10W 12.8A