313
Explicit Messages
Appendix A
Offset
Compensa-
tion after
Scaling
Write/
Read
Compensates for scal-
ing errors after scaling
with an offset value.
Write:
10 hex
Read:
0E hex
8F hex 01 to 40
hex
*1
71 hex
*2
99 hex
*3
2 bytes
(
−
28000 to
28000)
2 bytes
(
−
28000 to
28000)
Maximum
Value Read
Read/
Reset
Reads the maximum
value after power is
turned ON.
Read:
0E hex
Reset:
35 hex
8F hex 01 to 40
hex
*1
72 hex
*2
9A hex
*3
2 bytes
Minimum
Value Read
Read/
Reset
Reads the minimum
value after power is
turned ON.
Read:
0E hex
Reset:
35 hex
8F hex 01 to 40
hex
*1
73 hex
*2
9B hex
*3
2 bytes
Peak Value
Read
Read The peak value is held
and read.
0E hex
8F hex 01 to 40
hex
*1
74 hex
*2
9C hex
*3
2 bytes
Bottom
Value Read
Read The bottom value is
held and read.
0E hex
8F hex 01 to 40
hex
*1
75 hex
*2
9D hex
*3
2 bytes
Top Value
Read
Read The top value is held
and read.
0E hex
8F hex 01 to 40
hex
*1
76 hex
*2
9E hex
*3
2 bytes
Top Detec-
tion Timing
Flag Read
Read Reads the timing for
detecting top values.
0E hex
8F hex 01 to 40
hex
*1
77 hex
*2
9F hex
*3
1 byte
Valley
Value Read
Read The valley value is held
and read.
0E hex
8F hex 01 to 40
hex
*1
78 hex
*2
A0 hex
*3
2 bytes
Valley
Detection
Timing Flag
Read
Read Reads the timing for
detecting valley values.
0E hex
8F hex 01 to 40
hex
*1
79 hex
*2
A1 hex
*3
1 byte
HH Value
Setting
Write/
Read
Sets the HH value.
Write:
10 hex
Read:
0E hex
8F hex 01 to 40
hex
*1
7C hex
*2
A4 hex
*3
2 bytes
(
−
32768 to
32767)
2 bytes
(
−
32768 to
32767)
LL Value
Setting
Write/
Read
Sets the LL value.
Write:
10 hex
Read:
0E hex
8F hex 01 to 40
hex
*1
7D hex
*2
A5 hex
*3
2 bytes
(
−
32768 to
32767)
2 bytes
(
−
32768 to
32767)
H Value
Setting
Write/
Read
Sets the H value.
Write:
10 hex
Read:
0E hex
8F hex 01 to 40
hex
*1
7E hex
*2
A6 hex
*3
2 bytes
(
−
32768 to
32767)
2 bytes
(
−
32768 to
32767)
L Value
Setting
Write/
Read
Sets the L value.
Write:
10 hex
Read:
0E hex
8F hex 01 to 40
hex
*1
7F hex
*2
A7 hex
*3
2 bytes
(
−
32768 to
32767)
2 bytes
(
−
32768 to
32767)
Scaled
Analog
Input Value
Read
Read Reads analog input val-
ues for which have only
been scaled.
0E hex
8F hex 01 to 40
hex
*1
84 hex
*2
AC hex
*3
2 bytes
Rate of
Change
Value Read
Read Reads the rate of
change for each sam-
pling cycle.
0E hex
8F hex 01 to 40
hex
*1
85 hex
*2
AD hex
*3
2 bytes
Explicit
message
Read
/write
Function Command
Response
Service
code
Class
ID
Instance
ID
Attribute ID
Data
Summary of Contents for SMARTSLICE GRT1-DRT
Page 1: ...OPERATION MANUAL Cat No W455 E1 08 SmartSlice GRT1 Series Slice I O Units ...
Page 3: ...SmartSlice GRT1 Series Slice I O Units Operation Manual Revised December 2018 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 20: ...xx EC Directives 6 ...
Page 62: ...42 Connecting Turnback Cables Section 3 3 ...
Page 250: ...230 Maintenance Information Window Section 7 3 Maintenance Information Window ...
Page 292: ...272 GRT1 CP1 L Positioning Unit Section 7 5 ...
Page 300: ...280 GRT1 END End Unit Section 8 5 Dimensions 11 9 11 9 55 7 1 5 19 5 83 5 2 9 2 9 OMRON ...
Page 322: ...302 Troubleshooting by Unit Section 9 5 ...
Page 350: ...330 Explicit Messages Appendix A ...
Page 354: ...334 Power Consumption and Weight Tables Appendix C ...
Page 356: ...336 I O Current Consumption Table Appendix D ...
Page 364: ...344 Revision History ...
Page 365: ......