257
GRT1-CP1-L Positioning Unit
Section 7-5
GRT1-CP1-L Set to Line Driver Mode
Wiring
Connect the terminals of the Positioning Unit according to the following dia-
grams. The connections depend on the counter input signal interface that is
set.
A+
B+
Z+
OUT0
OUT1
G
(2x)
V
A
−
B
−
Z
−
IN
Base
b
lock
Internal
circ
u
its
Main
b
lock
I/O LED
Terminal
b
lock
Voltage
step-do
w
n
I/O LED (2x)
Internal
circ
u
its
B
N.C.
Z
N.C.
A
N.C.
IN
OUT0
V
OUT1
G
G
24-V rotary encoder
(all DIP s
w
itch pins ON)
Line driver rotary encoder
(all DIP s
w
itch pins OFF)
B+
Z+
A+
IN
V
G
B
−
Z
−
A
−
OUT0
OUT1
G
Summary of Contents for SMARTSLICE GRT1-DRT
Page 1: ...OPERATION MANUAL Cat No W455 E1 08 SmartSlice GRT1 Series Slice I O Units ...
Page 3: ...SmartSlice GRT1 Series Slice I O Units Operation Manual Revised December 2018 ...
Page 4: ...iv ...
Page 6: ...vi ...
Page 20: ...xx EC Directives 6 ...
Page 62: ...42 Connecting Turnback Cables Section 3 3 ...
Page 250: ...230 Maintenance Information Window Section 7 3 Maintenance Information Window ...
Page 292: ...272 GRT1 CP1 L Positioning Unit Section 7 5 ...
Page 300: ...280 GRT1 END End Unit Section 8 5 Dimensions 11 9 11 9 55 7 1 5 19 5 83 5 2 9 2 9 OMRON ...
Page 322: ...302 Troubleshooting by Unit Section 9 5 ...
Page 350: ...330 Explicit Messages Appendix A ...
Page 354: ...334 Power Consumption and Weight Tables Appendix C ...
Page 356: ...336 I O Current Consumption Table Appendix D ...
Page 364: ...344 Revision History ...
Page 365: ......