![Omron NC1-510000 User Manual Download Page 127](http://html1.mh-extra.com/html/omron/nc1-510000/nc1-510000_user-manual_742744127.webp)
Power Connector Wiring Materials
Use the power supply connector that was supplied to connect the power supply to the AMR Controller.
• Select power supply conductors with consideration to the voltage drop and heat generation for the
cable length at the installation environment.
• Always use twisted wires to minimize the occurrence of electrical disturbance.
• Recommended power supply conductor sizes are provided in the table.
Wire type
Conductor cross-section
Solid conductor
0.5 to 10 mm
2
Flexible conductor
0.5 to 6 mm
2
Flexible conductor, with ferrule and no plastic sleeve
0.5 to 6 mm
2
Flexible conductor, with ferrule and plastic sleeve
0.5 to 4 mm
2
Minimum AWG according to UL/cUL
20
Maximum AWG according to UL/cUL
8
• Power Supply Connector
DC Power Supply
The OMRON S8VK-series power supply is recommended for use with the AMR Controller.
Additional Information
• Refer to
on page 3-27 for more information.
• Refer to
4-1-3 Power Consumption Specifications
on page 4-4 for power consumption details.
5 Installation
5-29
AMR Controller User's Guide (I650)
5-4
W
ire
5
5-4-3
Wire the Power Connector
Summary of Contents for NC1-510000
Page 1: ...AMR Controller User s Guide NC1 510000 NC1 510001 AMR Controller I650 E 01...
Page 4: ...Introduction 2 AMR Controller User s Guide I650...
Page 36: ...1 Overview 1 6 AMR Controller User s Guide I650...
Page 156: ...7 Maintenance 7 8 AMR Controller User s Guide I650...
Page 183: ...I Index I 1 AMR Controller User s Guide I650 I...
Page 186: ...Index I 4 AMR Controller User s Guide I650...
Page 187: ......