![Omron NC1-510000 User Manual Download Page 182](http://html1.mh-extra.com/html/omron/nc1-510000/nc1-510000_user-manual_742744182.webp)
A-6 PLC Connector Pin Details
Pin details of the PLC connector.
1
5
6
10
11
15
The pin layout represents the PLC connector on the Mobile Robot layer of the AMR Controller.
Pin
Signal Name
Connects to
1
SIO_IN0
Safety output terminal So0 of NX-SOD400
2
0V
IOG terminal of NX-SOD400
3
0V
IOG terminal of Safety PLC
4
SIO_OUTTEST0
Test output terminal T0 of NX-SID800
5
SIO_OUT0
Safety input terminal Si0 of NX-SID800
6
0V
IOG terminal of Safety PLC (close to NX-SID800)
7
SIO_OUTTEST2
Test output terminal T0 of NX-SID800
8
SIO_OUT2
Safety input terminal Si2 of NX-SID800
9
SIO_OUTTEST1
Test output terminal T1 of NX-SID800
10
SIO_OUT1
Safety input terminal Si1 of NX-SID800
11
SIO_IN1
Safety output terminal So1 of NX-SOD400
12
0V
IOG terminal of NX-SOD400
13
0V
IOG terminal of Safety PLC (close to NX-SID800)
14
SIO_OUTTEST3
Test output terminal T1 of NX-SID800
15
SIO_OUT3
Safety input terminal Si3 of NX-SID800
*1.
Pin 3 must be connected with a terminal pin IOG of the Safety PLC as close as possible to the SID800 mod-
ule of this Safety PLC. The SID800 module itself has no IOG terminal.
Appendices
A-26
AMR Controller User's Guide (I650)
Summary of Contents for NC1-510000
Page 1: ...AMR Controller User s Guide NC1 510000 NC1 510001 AMR Controller I650 E 01...
Page 4: ...Introduction 2 AMR Controller User s Guide I650...
Page 36: ...1 Overview 1 6 AMR Controller User s Guide I650...
Page 156: ...7 Maintenance 7 8 AMR Controller User s Guide I650...
Page 183: ...I Index I 1 AMR Controller User s Guide I650 I...
Page 186: ...Index I 4 AMR Controller User s Guide I650...
Page 187: ......