![Omron NC1-510000 User Manual Download Page 131](http://html1.mh-extra.com/html/omron/nc1-510000/nc1-510000_user-manual_742744131.webp)
I/O Connector Wiring Procedure
Use the following procedure to wire the I/O connector.
1
Ensure the I/O connector is not connected to the AMR Controller.
2
Remove the sheath from the wires.
7 mm
Precautions for Safe Use
Observe the following precautions to prevent broken wires.
• When you remove the sheath, be careful not to damage the conductor.
• Connect the conductor without twisting the wires.
• Do not weld the conductors. Doing so may cause the wires to break with vibration.
3
Remove the I/O connector from the AMR Controller.
4
Insert a screwdriver in the small groove above the cable entry
1
to unlock the cable entry and
then push the wire all the way to the back of the cable opening
2
.
1
2
5
Remove the screwdriver.
Do not apply stress to the cable after you have connected the wires.
5 Installation
5-33
AMR Controller User's Guide (I650)
5-4
W
ire
5
5-4-4
Wire the I/O Connector