Fan
Forced Air Circulation
OMRON
product
OMRON
product
Room Cooling
Cool the entire room where the control panel is located.
Room Cooling
Cooler
Control panel
Low Temperatures
The AMR Controller may not start normally if the temperature is below 0°C when the power is turned
ON. Maintain an air temperature of at least 5°C inside the panel, by implementing measures such as
installing a low-capacity space heater in the panel.
Alternatively, leave the AMR Controller power ON to keep the AMR Controller warm.
5-3-4
Humidity
Rapid temperature changes can cause condensation to occur, resulting in malfunctioning due to short-
circuiting.
When there is a possibility of this occurring, take measures against condensation, such as leaving the
AMR Controller power ON at night or installing a heater in the control panel to keep it warmer.
Moisture
absorber
Power ON
Control panel
Heater
Examples of Measures against Condensation
OMRON
product
5-3-5
Vibration and Shock
The AMR Controller is tested for conformity with the sine wave vibration test method (IEC 60068-2-6)
and the shock test method (IEC 60068-2-27) of the Environmental Testing for Electrotechnical
5 Installation
5-11
AMR Controller User's Guide (I650)
5-3 Mount
5
5-3-4
Humidity
Summary of Contents for NC1-510000
Page 1: ...AMR Controller User s Guide NC1 510000 NC1 510001 AMR Controller I650 E 01...
Page 4: ...Introduction 2 AMR Controller User s Guide I650...
Page 36: ...1 Overview 1 6 AMR Controller User s Guide I650...
Page 156: ...7 Maintenance 7 8 AMR Controller User s Guide I650...
Page 183: ...I Index I 1 AMR Controller User s Guide I650 I...
Page 186: ...Index I 4 AMR Controller User s Guide I650...
Page 187: ......