Ground Connection Details
This section provides details about the ground connection.
Use the functional ground terminal on the mounting bracket(s) to ground your AMR Controller.
The washers and nut
C
are supplied with the bracket(s).
Items Supplied with the Brackets
on page 5-4 for details.
Custom Mount
The AMR Controller has on one side light grey circles around the threaded mounting holes. The cus-
tom bracket has on the inside on one side also the light grey circles around the mounting holes.
The light grey circles are contact areas that ensure a good electrical conductivity.
Position the AMR Controller inside the bracket so the light grey circles of the custom bracket contact
the light grey circles of the AMR Controller.
Book Mount
7
B
A
C
Mount the ground connection wire
B
to the functional ground terminal
A
using the washers and nut
C
. Tighten the nut with a torque of 1.2 N·m max.