![Omron NC1-510000 User Manual Download Page 18](http://html1.mh-extra.com/html/omron/nc1-510000/nc1-510000_user-manual_742744018.webp)
Cautions
CAUTION
Wiring
The product has an internal non-isolated DC power supply. Circuit ground (0 VDC) and
frame ground are connected together. When connecting a non-isolated device or a non-
isolated interface to the product, take appropriate actions to avoid communication fail-
ures or damage to the mentioned ports.
Industrial PC Platform Product
Non-isolated
Device
Non-isolated
Interface
24 VDC
0 VDC
Never ground the 24 VDC side of the power supply. This may cause a short circuit.
Safety Precautions
16