![Omron NC1-510000 User Manual Download Page 125](http://html1.mh-extra.com/html/omron/nc1-510000/nc1-510000_user-manual_742744125.webp)
7
B
A
C
Mount the ground connection wire
B
to the functional ground terminal
A
using the washers and nut
C
. Tighten the nut with a torque of 1.2 N·m max.
on page 5-19 for wall mounting details.
Crimp terminals
Use crimp terminals with dimensions X = M4 and Y = 8 mm max.
Y
X
Y
X
5-4-3
Wire the Power Connector
This section describes how to wire the power connector.
Precautions for Safe Use
• Do not perform a dielectric strength test.
• Always use the recommended uninterruptible power supply (UPS) to prevent data loss and
other system file integrity issues caused by unexpected power interruption. Back up the sys-
tem files in the planned way to prevent data loss and other system file integrity issues caused
by incorrect operation.
5 Installation
5-27
AMR Controller User's Guide (I650)
5-4
W
ire
5
5-4-3
Wire the Power Connector