Power Connector Wiring Procedure
Use the following procedure to wire the power connector.
1
Ensure the power connector is not connected to the AMR Controller.
2
Remove the sheath from the power supply wires.
7 mm
Precautions for Safe Use
Observe the following precautions to prevent broken wires.
• When you remove the sheath, be careful not to damage the conductor.
• Connect the conductor without twisting the wires.
• Do not weld the conductors. Doing so may cause the wires to break with vibration.
3
Insert a 2.5 mm flat-blade screwdriver in the small opening above the cable opening
1
to un-
lock the cable entry and then push the wire all the way to the back of the cable opening
2
.
2
1
1
2
Pin
Description
1
24 VDC
2
0 VDC
4
Remove the screwdriver.
Do not apply stress to the cable after you have connected the wires.