7-1 Standard Specification List
7
Specifications
*1. To operate the motor at over 50/60 Hz, contact the motor manufacturer to find out the maximum allowable
number of revolutions.
*2. For the stable control of the motor, the output frequency may exceed the maximum frequency set in A004
(A204) by 2 Hz max.
Outpu
t sign
al
Multi-function output
RUN (signal during operation), FA1 (frequency arrival signal), FA2 (over set
frequency arrival signal), OL (overload warning signal), OD (PID excess deviation
signal), AL (alarm output), DC (analog input disconnection detection signal), FBV
(PID FB status output), NDc (network error), LOG (logical operation result), ODc (Do
not use.), LOC (light load detection signal)
Frequency monitor
Analog output (0 to 10 V DC, 1 mA max.),
Frequency/Current signals are selectable via the AM output terminal.
Relay output
The relay (SPDT contact) outputs signals corresponding to the multi-function output.
Other function
s
AVR function, V/f characteristic selection, upper/lower limit, 16-step speeds, starting frequency adjustment,
jogging operation, carrier frequency adjustment, PID control, frequency jump, analog gain/bias adjustment, S-
shape acceleration/deceleration, electronic thermal characteristics/level adjustment, retry function, simplified
torque boost, trip monitor, soft lock function, frequency conversion display, USP function, 2nd control function,
motor rotation speed UP/DWN, overcurrent suppression function
Gen
eral speci
fic
a
tions
Ambient temperature
-10
°
C to 50
°
C (Both the carrier frequency and output current need to be reduced at
over 40
°
C.)
Ambient storage
temperature
-20
°
C to 65
°
C (short-time temperature during transport)
Humidity
20% to 90% RH
Vibration
5.9 m/s
2
(0.6G), 10 to 55 Hz (Complies with the test method specified in JIS C0040
(1999).)
Location
At a maximum altitude of 1,000 m; indoors (without corrosive gases or dust)
Applicable standard
Complies with UL, cUL, CE standards. (Insulation distance)
Options
Noise filter, AC/DC reactors, regenerative braking unit and resistor, etc.
Item
Specifications
Summary of Contents for JX-A4004
Page 2: ......
Page 16: ...14 About This Manual ...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 1 2 Appearance and Names of Parts 1 4 ...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 2 2 2 Wiring 2 7 ...
Page 79: ...Chapter 4 Functions 4 1 Monitor Mode 4 2 4 2 Function Mode 4 6 ...
Page 174: ...5 8 5 2 Troubleshooting 5 Maintenance Operations ...
Page 175: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 2 6 2 Storage 6 8 ...
Page 199: ...Appendix Appendix 1Parameter ListApp 2 Appendix 2Product Life CurveApp 18 ...
Page 217: ...INDEX ...
Page 220: ......