![background image](http://html.mh-extra.com/html/omron/jx-a4004/jx-a4004_user-manual_742715106.webp)
4-28
4-2 Function Mode
4
Func
tions
Acceleration/Deceleration Pattern
This function is used when smooth acceleration/deceleration is needed.
•Acceleration/deceleration pattern can be set according to each system.
External Frequency Adjustment Function (OI)
For each item, refer to "External Frequency (Voltage/Current) Adjustment" (page 4-11).
Parameter No.
Function name
Data
Default setting
Unit
A097
Acceleration pattern
selection
00: Line
01: S-shape curve
00
⎯
A098
Deceleration pattern
selection
00: Line
01: S-shape curve
00
⎯
Parameter No.
Set value
00
01
Line
S-shape curve
A097
(Acceleration)
A098
(Deceleration)
Description
Accelerates/Decelerates linearly before reaching
the set output frequency value.
Helps prevent the collapse of cargo on the
elevating machine or conveyor.
Output frequency
Time
Output frequency
Time
Output frequency
Time
Output frequency
Time
Parameter No.
Function name
Data
Default setting
Unit
A101
OI start frequency
0.00 to 400.0
0.0
Hz
A102
OI end frequency
0.00 to 400.0
0.0
Hz
A103
OI start ratio
0. to 100.
0.
%
A104
OI end ratio
0. to 100.
100.
%
A105
OI start selection
00: External start selection
01: 0 Hz
01
⎯
Related parameters
A005, A011 to A015, A016, A151 to A155, AT input
Summary of Contents for JX-A4004
Page 2: ......
Page 16: ...14 About This Manual ...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 1 2 Appearance and Names of Parts 1 4 ...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 2 2 2 Wiring 2 7 ...
Page 79: ...Chapter 4 Functions 4 1 Monitor Mode 4 2 4 2 Function Mode 4 6 ...
Page 174: ...5 8 5 2 Troubleshooting 5 Maintenance Operations ...
Page 175: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 2 6 2 Storage 6 8 ...
Page 199: ...Appendix Appendix 1Parameter ListApp 2 Appendix 2Product Life CurveApp 18 ...
Page 217: ...INDEX ...
Page 220: ......