
3-26
3-6 Parameter List
3
Operation
Multi-
function input ter
m
in
als
C011
Multi-function input 1
operation selection
00: NO
01: NC
00
No
⎯
110B
4-44
C012
Multi-function input 2
operation selection
00
110C
C013
Multi-function input 3
operation selection
00
110D
C014
Multi-function input 4
operation selection
00
110E
C015
Multi-function input 5
operation selection
00
110F
Multi-
function
output setting
C021
Multi-function output
terminal 11 selection
00: RUN (signal during RUN)
01: FA1 (constant speed arrival signal)
02: FA2 (over set frequency arrival signal)
03: OL (overload warning)
04: OD (excessive PID deviation)
05: AL (alarm output)
06: Dc (disconnection detection)
07: FBV (PID FB status output)
08: NDc (network error)
09: LOG(logic operation output)
10: ODc (Do not use.)
43: LOC (light load detection signal)
00
No
⎯
1114
4-55
C026
Relay output (AL2,
AL1) function
selection
05
1119
C028
AM selection
00: Output frequency
01: Output current
00
No
⎯
111B
4-62
C031
Multi-function output
terminal 11 contact
selection
00: NO contact at AL2; NC contact at AL1
01: NC contact at AL2; NO contact at AL1
00
No
⎯
111D
4-61
C036
Relay output (AL2,
AL1) contact
selection
01
1122
C038
Light load signal
output mode
00: Enabled during acceleration/deceleration/
constant speed
01: Enabled only during constant speed
01
No
⎯
1178
4-60
C039
Light load detection
level
0.0 to 2.0 × Rated current (0.0 setting: Function
disable)
Rated
current
No
⎯
1179
4-60
L
evel output
status setting
C041
Overload warning
level
0.0: Does not operate
0.1 × Rated current to 2.0 × Rated current
Rated
current
No
A
1124
4-33
C241
*2nd overload
warning level
Rated
current
153A
C042
Arrival frequency
during acceleration
0.0 to 400.0
0.0
No
Hz
1126
4-56
C043
Arrival frequency
during deceleration
0.0 to 400.0
0.0
No
Hz
1128
4-56
C044
PID deviation
excessive level
0.0 to 100.0
3.0
No
%
1129
4-22
C052
PID FB upper limit
0.0 to 100.0
100
No
%
112E
4-22
C053
PID FB lower limit
0.0
112F
Parameter
No.
Function name
Monitor or data range
(Digital Operator)
Default
setting
Change
during
Run
Unit
Modbus
Address
(Hex)
Page
Summary of Contents for JX-A4004
Page 2: ......
Page 16: ...14 About This Manual ...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 1 2 Appearance and Names of Parts 1 4 ...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 2 2 2 Wiring 2 7 ...
Page 79: ...Chapter 4 Functions 4 1 Monitor Mode 4 2 4 2 Function Mode 4 6 ...
Page 174: ...5 8 5 2 Troubleshooting 5 Maintenance Operations ...
Page 175: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 2 6 2 Storage 6 8 ...
Page 199: ...Appendix Appendix 1Parameter ListApp 2 Appendix 2Product Life CurveApp 18 ...
Page 217: ...INDEX ...
Page 220: ......