![background image](http://html.mh-extra.com/html/omron/jx-a4004/jx-a4004_user-manual_742715159.webp)
4-81
4-2 Function Mode
4
Functions
103Dh
Multi-step speed
reference 10
A030
R/W
0.0/Starting frequency to 4000
0.1 [Hz]
103Fh
Multi-step speed
reference 11
A031
R/W
1041h
Multi-step speed
reference 12
A032
R/W
1043h
Multi-step speed
reference 13
A033
R/W
1045h
Multi-step speed
reference 14
A034
R/W
1047h
Multi-step speed
reference 15
A035
R/W
1048h
Jogging frequency
A038
R/W
0 to 999
0.01 [Hz]
1049h
Jogging stop selection
A039
R/W
00: Free-run stop
01: Deceleration stop
02: DC injection braking stop
⎯
104Ah
Torque boost selection
A041
R/W
00: Manual torque boost only
01: Simple torque boost
⎯
1510h
2nd torque boost selection
A241
R/W
104Bh
Manual torque boost voltage
A042
R/W
0 to 200
0.1 [%]
1511h
2nd manual torque boost
voltage
A242
R/W
104Ch
Manual torque boost
frequency
A043
R/W
0 to 500
0.1 [%]
1512h
2nd manual torque boost
frequency
A243
R/W
104Dh
V/f characteristics selection
A044
R/W
00: VC
01: 1.7th power of VP
06: Special VP
⎯
1513h
2nd V/f characteristics
selection
A244
R/W
104Eh
Output voltage gain
A045
R/W
20 to 100
1. [%]
1514h
2nd output voltage gain
A245
R/W
1051h
DC injection braking
selection
A051
R/W
00: Disabled
01: Enabled during stop
02: Output frequency<A052 DB
⎯
1052h
DC injection braking
frequency
A052
R/W
0 to 600
0.1 [Hz]
1053h
DC injection braking delay
time
A053
R/W
0 to 50
0.1 [s]
1054h
DC injection braking power
A054
R/W
0 to 100
1. [%]
1055h
DC injection braking time
A055
R/W
0 to 600
0.1 [s]
1056h
DC injection braking method
selection
A056
R/W
00: Edge operation
01: Level operation
⎯
105Ah
Frequency upper limit
A061
R/W
0.0/Frequency lower limit
: A062 x 10 to Maximum frequency
: A004 x 10
0.1 [Hz]
1517h
2nd frequency upper limit
A261
R/W
0.0/2nd frequency lower limit
: A262 x 10 to 2nd max. frequency
: A204 x 10
0.1 [Hz]
105Bh
Frequency lower limit
A062
R/W
0.0/Starting frequency
: b082 × 10 to Frequency upper limit
: A061 × 10
0.1 [Hz]
1518h
2nd frequency lower limit
A262
R/W
0.0/Starting frequency
: b082 x 10 to 2nd frequency upper limit
: A261x10
0.1 [Hz]
Register
No.
Function name
Parameter
No.
R/W
Function
Monitor or data range
Resolution
Summary of Contents for JX-A4004
Page 2: ......
Page 16: ...14 About This Manual ...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 1 2 Appearance and Names of Parts 1 4 ...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 2 2 2 Wiring 2 7 ...
Page 79: ...Chapter 4 Functions 4 1 Monitor Mode 4 2 4 2 Function Mode 4 6 ...
Page 174: ...5 8 5 2 Troubleshooting 5 Maintenance Operations ...
Page 175: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 2 6 2 Storage 6 8 ...
Page 199: ...Appendix Appendix 1Parameter ListApp 2 Appendix 2Product Life CurveApp 18 ...
Page 217: ...INDEX ...
Page 220: ......