3-20
3-6 Parameter List
3
Operation
Chara
ct. T
orque
boost
A043
Manual torque boost
frequency
0.0 to 50.0
2.5
Yes
%
104C
4-15
A243
*2nd manual torque
boost frequency
0.0
1512
A044
V/f characteristics
selection
00: Constant torque characteristics (VC)
01: Reduced torque characteristics (VP 1.7th
power)
06: Special reduced torque characteristics
(Special VP)
00
No
-
104D
4-15
A244
*2nd V/f
characteristics
selection
00
1513
A045
Output voltage gain
20. to 100.
100.
Yes
%
104E
4-15
4-63
A245
*2nd output voltage
gain
100.
1514
4-15
DC injection bra
king
A051
DC injection braking
selection
00: Disabled
01: Enabled
02: Frequency control [A052 set value]
00
No
⎯
1051
4-17
A052
DC injection braking
frequency
0.0 to 60.0
0.5
No
Hz
1052
4-17
A053
DC injection braking
delay time
0.0 to 5.0
0.0
No
s
1053
4-17
A054
DC injection braking
power
0. to 100.
50
No
%
1054
4-17
A055
DC injection braking
time
0.0 to 60.0
0.5
No
s
1055
4-17
A056
DC injection braking
method selection
00: Edge operation
01: Level operation
01
No
⎯
1056
4-17
Upper
/Lower
limit, Jump
A061 Frequency upper limit
0.0/Frequency lower limit to Max. frequency
0.0
No
Hz
105A
4-20
A261
*2nd frequency upper
limit
0.0/Frequency lower limit to 2nd Max. frequency
0.0
1517
A062 Frequency lower limit 0.0/Starting frequency to Frequency upper limit
0.0
No
Hz
105B
4-20
A262
*2nd frequency lower
limit
0.0/Starting frequency to 2nd frequency upper
limit
0.0
1518
A063
Jump frequency 1
Jump frequency: 0.0 to 400.0
Jump frequency width: 0.0 to 10.0
0.0
No
Hz
105D
4-21
A064
Jump frequency
width 1
0.5
105E
A065
Jump frequency 2
0.0
1060
A066
Jump frequency
width 2
0.5
1061
A067
Jump frequency 3
0.0
1063
A068
Jump frequency
width 3
0.5
1064
PID control
A071
PID selection
00: Disabled
01: Enabled
00
No
⎯
1068
4-22
A072
PID P gain
0.2 to 5.0
1.0
Yes
⎯
1069
4-22
A073
PID I gain
0.0 to 150.0
1.0
Yes
s
106A
4-22
A074
PID D gain
0.00 to 100.0
0.0
Yes
s
106B
4-22
A075
PID scale
0.01 to 99.99
1.00
No
Time
106C
4-22
A076
PID feedback
selection
00: OI
01: O
02: RS485 communication
10: Operation function output
00
No
⎯
106D
4-22
Parameter
No.
Function name
Monitor or data range
(Digital Operator)
Default
setting
Change
during
Run
Unit
Modbus
Address
(Hex)
Page
Summary of Contents for JX-A4004
Page 2: ......
Page 16: ...14 About This Manual ...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 1 2 Appearance and Names of Parts 1 4 ...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 2 2 2 Wiring 2 7 ...
Page 79: ...Chapter 4 Functions 4 1 Monitor Mode 4 2 4 2 Function Mode 4 6 ...
Page 174: ...5 8 5 2 Troubleshooting 5 Maintenance Operations ...
Page 175: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 2 6 2 Storage 6 8 ...
Page 199: ...Appendix Appendix 1Parameter ListApp 2 Appendix 2Product Life CurveApp 18 ...
Page 217: ...INDEX ...
Page 220: ......