![background image](http://html.mh-extra.com/html/omron/jx-a4004/jx-a4004_user-manual_742715206.webp)
App-8
Appendix-1 Parameter List
RU
N mod
e, Accele
ration/De
ce
leratio
n
fun
cti
ons
A085
RUN mode
selection
00: Normal operation
01: Energy-saving operation
00
No
-
A086
Energy-saving
response/
accuracy
adjustment
0 to 100
50
No
%
A092
Acceleration time
2
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
15.00
Yes
s
A292
*2nd acceleration
time 2
15.00
A093
Deceleration
time 2
0.01 to 99.99
100.0 to 999.9
1000. to 3000.
15.00
Yes
s
A293
*2nd deceleration
time 2
15.00
A094
2-step
acceleration/
deceleration
selection
00: Switched via multi-function input 09 (2CH)
01: Switched by setting
00
No
⎯
A294
*2nd 2-step
acceleration/
deceleration
selection
00
A095
2-step
acceleration
frequency
0.0 to 400.0
0.0
No
Hz
A295
*2nd 2-step
acceleration
frequency
0.0
A096
2-step
deceleration
frequency
0.0 to 400.0
0.0
No
Hz
A296
*2nd 2-step
deceleration
frequency
0.0
A097
Acceleration
pattern selection
00: Line
01: S-shape curve
00
No
⎯
A098
Deceleration
pattern selection
00: Line
01: S-shape curve
00
No
⎯
Parameter
No.
Function name
Monitor or data range
(Digital Operator)
Default
setting
Changes
during
operation
Unit
Set
value
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.
Summary of Contents for JX-A4004
Page 2: ......
Page 16: ...14 About This Manual ...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 1 2 Appearance and Names of Parts 1 4 ...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 2 2 2 Wiring 2 7 ...
Page 79: ...Chapter 4 Functions 4 1 Monitor Mode 4 2 4 2 Function Mode 4 6 ...
Page 174: ...5 8 5 2 Troubleshooting 5 Maintenance Operations ...
Page 175: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 2 6 2 Storage 6 8 ...
Page 199: ...Appendix Appendix 1Parameter ListApp 2 Appendix 2Product Life CurveApp 18 ...
Page 217: ...INDEX ...
Page 220: ......