App-16
Appendix-1 Parameter List
Communica
tion fu
nction ad
justme
nt
C070
Operator/ModBus
selection
02: Digital Operator
03: ModBus
02
No
⎯
C071
Communication
speed selection
(Baud rate
selection)
04: 4800 bps
05: 9600 bps
06: 19200 bps
04
No
⎯
C072
Communication
station No.
selection
1. to 32.
1.
No
⎯
C074
Communication
parity selection
00: No parity
01: Even
02: Odd
00
No
⎯
C075
Communication
stop bit selection
1: 1-bit
2: 2-bit
1
No
⎯
C076
Communication
error selection
00: Trip
01: Trip after deceleration stop
02: Ignore
03: Free run
04: Deceleration stop
02
No
⎯
C077
Communication
error timeout
0.00 to 99.99
0.00
No
s
C078
Communication
wait time
0. to 1000.
0.
No
ms
Va
rious adj
ustmen
t
C081
O adjustment
0.0 to 200.0
100.0
Yes
%
C082
OI adjustment
0.0 to 200.0
100.0
Yes
%
Parameter
No.
Function name
Monitor or data range
(Digital Operator)
Default
setting
Changes
during
operation
Unit
Set
value
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.
Summary of Contents for JX-A4004
Page 2: ......
Page 16: ...14 About This Manual ...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 1 2 Appearance and Names of Parts 1 4 ...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 2 2 2 Wiring 2 7 ...
Page 79: ...Chapter 4 Functions 4 1 Monitor Mode 4 2 4 2 Function Mode 4 6 ...
Page 174: ...5 8 5 2 Troubleshooting 5 Maintenance Operations ...
Page 175: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 2 6 2 Storage 6 8 ...
Page 199: ...Appendix Appendix 1Parameter ListApp 2 Appendix 2Product Life CurveApp 18 ...
Page 217: ...INDEX ...
Page 220: ......