![background image](http://html.mh-extra.com/html/omron/jx-a4004/jx-a4004_user-manual_742715215.webp)
App-17
Appendix-1 Parameter List
Others
C086
AM offset
adjustment
0.0 to 10.0
0.0
Yes
V
C091
Not used
Use "00".
*Do not change.
00
⎯
⎯
C101
UP/DWN selection
00: Do not store the frequency data
01: Store the frequency data
00
No
⎯
C102
Reset selection
00: Trip reset at power-on
01: Trip reset when the power is OFF
02: Enabled only during trip (Reset when the
power is ON.)
00
No
⎯
C141
Logic operation
function A input
00: RUN (signal during RUN)
01: FA1 (constant speed arrival signal)
02: FA2 (over set frequency arrival signal)
03: OL (overload warning)
04: OD (excessive PID deviation)
05: AL (alarm output)
06: Dc (disconnection detected)
07: FBV (PID FB status output)
08: NDc (network error)
10: ODc (Do not use.)
43: LOC (light load detection signal)
00
No
⎯
C142
Logic operation
function B input
01
No
⎯
C143
Logic operator
selection
00: AND
01: OR
02: XOR
00
No
⎯
C144
Output terminal 11
ON delay
0.0 to 100.0
0.0
No
s
C145
Output terminal 11
OFF delay
0.0 to 100.0
0.0
No
s
C148
Relay output ON
delay
0.0 to 100.0
0.0
No
s
C149
Relay output OFF
delay
0.0 to 100.0
0.0
No
s
Control parameter
H003
Motor capacity
selection
200-V class
0.2/0.4/0.75/1.5/2.2/3.7/5.5/7.5
400-V class
0.4/0.75/1.5/2.2/3.7/5.5/7.5
Factory
default
No
kW
H203
*2nd motor
capacity selection
Factory
default
H004
Motor pole number
selection
2
4
6
8
4
No
Pole
H204
*2nd motor pole
number selection
4
H006
Stabilization
parameter
0. to 255.
100
Yes
%
H206
*2nd stabilization
parameter
100
Yes
%
Parameter
No.
Function name
Monitor or data range
(Digital Operator)
Default
setting
Changes
during
operation
Unit
Set
value
* 2nd control is displayed when SET (08) is allocated to one of from C001 to C005.
Summary of Contents for JX-A4004
Page 2: ......
Page 16: ...14 About This Manual ...
Page 19: ...Chapter 1 Overview 1 1 Functions 1 2 1 2 Appearance and Names of Parts 1 4 ...
Page 24: ......
Page 25: ...Chapter 2 Design 2 1 Installation 2 2 2 2 Wiring 2 7 ...
Page 79: ...Chapter 4 Functions 4 1 Monitor Mode 4 2 4 2 Function Mode 4 6 ...
Page 174: ...5 8 5 2 Troubleshooting 5 Maintenance Operations ...
Page 175: ...Chapter 6 Inspection and Maintenance 6 1 Inspection and Maintenance 6 2 6 2 Storage 6 8 ...
Page 199: ...Appendix Appendix 1Parameter ListApp 2 Appendix 2Product Life CurveApp 18 ...
Page 217: ...INDEX ...
Page 220: ......