8.2 Warning Displays
138
8.2
Warning Displays
Warning displays, with their names and meanings, are listed below.
Warning
Display
Warning Name
Meaning
A.910
Overload
This warning occurs before the overload alarm
(A.710 or A.720) occurs. If the warning is ignored
and operation continues, an overload alarm may
occur.
A.94A
MECHATROLINK-
II
Data Setting
Warning 1
An incorrect parameter number was set in the com-
mand.
A.94b
MECHATROLINK-
II
Data Setting
Warning 2
The command data is out of range.
A.94d
MECHATROLINK-
II
Data Setting
Warning 4
Unmatched data size was detected.
A.95A
MECHATROLINK-
II
Command Warn-
ing 1
A command was sent though the command sending
conditions were not satisfied.
A.95b
MECHATROLINK-
II
Command Warn-
ing 2
An unsupported command was sent.
A.95d
MECHATROLINK-
II
Command Warn-
ing 4
A command, especially latch command, interferes.
A.95E
MECHATROLINK-
II
Command Warn-
ing 5
A sub command and main command interfere.
A.960
MECHATROLINK-
II
Communications
Warning
A communications error occurred during MECHA-
TROLINK communications.