2.2 Installation Method
18
2.2
Installation Method
Installation Method and Direction
• Install the SERVOPACK perpendicular to the wall.
• Connect the mounting holes securely to the mounting surface with M4 screws.
Space between SERVOPACK Units
• Be sure to keep a space between adjacent SERVOPACK units as shown the following figure if they
are mounted inside the control panel. This allows the units to cool.
• Do not cover the inlet or outlet parts of the SERVOPACK and prevent any foreign objects, such as
metallic fragment, or combustibles from entering the product.
Failure to observe this caution may cause internal elements to deteriorate resulting in malfunction
or fire.
SERVOPACK installation plate
M4 screw
M4 screw
M4 screw
SJDE-08ANA-OY: Three mounting holes
SJDE-01 to 04ANA-OY: Two mounting holes
SERVOPACK installation plate
M4 screw
M4 screw
CAUTION
50 mm
min.
50 mm
min.
30 mm
min.
10 mm
min.
Air outlet
direction
Air inlet
direction