117
• 1. Run continuously (basic jog operation). To set the
jog speed you need to enter the value in the Jog
Speed edit box inside the “Run Continuous” Tab.
After setting the desired value, click on “Servo On”
button in the motor operation toolbar
Then you can click on “Forward” or “Reverse” to start
the JOG operation. The jog speed is monitored in the
motor operation tool bar. You can click on the Stop but-
ton to stop the jog operation.
If you want to swith to a different switch Run operation
use the following method:
Click the Servo Off button to disable the servo.
2. Run for n cycles (where you can set up to 10 differ-
ent steps for a complex run operation).
When you select “Run for n cycles the second tab “Run
Cycles” is selected.
You will find a grid where you can set the desired Jog
steps: for each step you can define the acceleration,
deceleration and run time and the jog speed.
Click on “Run Forward” or Run Reverse” to start the
operation.
Finally you can use the Test Run View for the Search
Origin operation. Once you have the search Origin
operation selected, set the Servo in On state by click-
ing “Servo On”. Then click on “Forward” or “Reverse”
button to start the Search Origin operation. A text mes-
sage with the result of the operation will be displayed in
the output window.
(cont’d)
Procedure
Descriptions
TOEP_C710806_03A_1_0.book Seite 117 Montag, 2. Juli 2007 3:55 15