4.2 Main Commands
66
Each alarm code of the JUNMA-series SERVOPACK is 2-byte long. The data format of alarm code is as
follows.
Note: 1. When ALM_RD_MOD = 0 or 1, the alarm code (1-byte long) is returned.
2. When ALM_RD_MOD = 2 or 3, the alarm code (2-byte long) is returned.
4.2.8 Clear Alarm or Warning (ALM_CLR: 06H)
* Alarm occurrence history is saved in non-volatile memory, and will not be lost if power goes OFF.
Details of ALM_CLR_MOD
D15-D12
D11-D4
D3-D0
Reserved (0)
Alarm code
Detailed information
Byte
ALM_CLR
Description
Command
Response
1
06H
06H
Processing clas-
sifications
Control com-
mand group
Synchronization
classifications
Asynchronous
2
−
ALARM
Processing time
Refer to
Details of
ALM_CLR_MO
D
Subcommand
Cannot be used
3
STATUS
• Clears the following alarm or warning status.
-Current alarm/warning status
-Alarm status history * (warning history is not preserved.)
• The ALM_CLR_MOD specifications are shown in the following table.
• A warning will occur and the command will be ignored in the following
cases.
-If parameters are changed mid-operation with CX-Drive: Command
warning 1 (A.95A)
-If ALM_CLR_MOD is not within range: Data setting warning 2 (A.94B)
4
5
ALM_CLR_
MOD
ALM_CLR_
MOD
6
−
−
7
8
9
10
11
12
13
14
15
16
WDT
RWDT
ALM_CLR_MOD
Description
Processing Time
0
Clear current alarm/warning status
Within 200 ms
1
Clear alarm status history
Within 2 s
TOEP_C710806_03A_1_0.book Seite 66 Montag, 2. Juli 2007 3:55 15