12. Appendix
12-29
Event Log File
12.9.3.
EQ100 saves error detection, monitoring function, and operation status changes with the
occurred hour as event log files for its device management function.
The event log files can be externally outputted by using EQ-Manager or Web UI operation.
They can be viewed on the Web screen.
Up to 640 logs are collected. When exceeded, older logs are deleted, from the oldest one.
<Event Log File Format>
- File name: "event_log_" + [SNC ID] + "_" + [YYYYMMDDHHMMSS] ".csv"
- File format: CSV, UTF-8 (No BOM) code, LF linefeed
(If the language is configured as Japanese, shift-jis and CRLF linefeed)
- Component:
900001
->SNC ID
DATE,TIME, CODE,DATA
-> Label: "DATE","TIME","CODE","DATA"
2010/05/01,01:13:27,30,005006,Abnormal battery voltage occurred, Open the top cover and
replace the battery within 5 minutes.
2010/05/01,00:02:40,92,000005,New setup registration/update,
:
DATE : Occurred date, 10 characters
TIME : Occurred time, 8 characters
CODE : Log code
DATA : Internal code, event name, action (if any)