6. Measurement Device Setup and Connection
6-4
To a wireless slave unit of command-response communications (CompoWay/F)(WZ-SRS01),
an RS-485-connected measurement device is connected. In such a case, a combination of its
group ID, wireless unit ID, and the unit number of the RS-485-connected measurement device
(CompoWay/F) is its identifier.
When the setting of wireless device unit is finished, make sure to connect a computer and the
wireless unit master and use the setup software WZ Manager (included in accessory CD-ROM
of WZ-MLAN01) for check the connection before connecting EQ100 and the wireless unit
master. This should make problem isolation easier between the wireless device unit and EQ100
when a problem occurs.
Precautions for
Correct Use
- Before using a wireless device, perform a wireless connection test at the site to install to
check normal communications.
■
Required Setup Items of Measurement Devices
Shown below are setup items of measurement devices required to connect to EQ100.
Shown below are setup items for communications with EQ100 and measurement operation of
measurement devices.
For details of configuration, refer to measurement devices' manuals.
Type
Name (Model)
Setup for EQ100
Connection
Basic Measurement Setup for
Measurement Devices
RS-485
-Connected
Measurement
Device
Smart Power Monitor
(KM20-B40-FLK)
- CompoWay/F Unit
Number
- Communication
Speed
- Others (data
length, stop bits,
vertical parity,
transmission wait
time)
Special CT, VT ratio, rated primary
current value
Smart Power Monitor
(KM100-T
-FLK)
Applied circuit, voltage range, current
range, VT primary voltage, CT ratio
Smart Power Monitor
(KM50-
-FLK)
Applied circuit, voltage range, current
range, VT primary voltage, CT ratio,
dedicated CT type, communications
protocol, measurement start time,
measurement end time
Power Measurement Unit
(KM1-PMU1A-FLK)
Electrical system 1 applicable phase
wire, measurement block, special CT,
electrical system 1 VT ratio,
measurement block 1 CT ratio,
measurement start time,
measurement end time, active input
setting
Dual Power System
Measurement Unit
(KM1-PMU2A-FLK)
Electrical system 1/2 applicable
phase wire, measurement block 1/2
special CT, electrical system 1/2 VT
ratio, measurement block 1/2 CT
ratio, measurement start time,
measurement end time, active input
setting
Pulse/Temperature Input
Unit
(KM1-EMU8A-FLK)
Event input 1-7 NPN/PNP input mode
settings, event input settings 1-7,
event input 1-7 input mode setting,
temperature unit, temperature
compensation 1, pulse conversion
coefficient settings 1-7, active input
setting