11. Safe Mode
11-9
11.6. Recovering to Factory Shipment Status
Resets all data of EQ100 (including the firmware) to the factory shipment status.
See below for operation steps:
1) Click [Initialization] in the factory shipment status.
2) On the message prompting process confirmation, click [OK].
3) When the EQ100 is reset to the factory shipment status, a message prompting restart
appears. Click [OK].
4) Configure the DIP switch SW10 on the EQ100 front end as OFF.
5) Use a very fine screwdriver or other tools to press and hold the reset button on the EQ100
front end for 1 second or longer.
A buzzer is sounded and EQ100 is reset. EQ100 is started with the factory shipment status.
Precautions for
Correct Use
- Before recovering to the factory shipment status, output EQ project files as well as collected
data files and event log files to the computer or an SD card.
RESET Button