![background image](http://html1.mh-extra.com/html/omron/cj1w-fln22/cj1w-fln22_operation-manual_742497258.webp)
232
FL-net Unit Support Software Ver. 1.6
Appendix F
(6) Sub-net mask (Default: 255.255.255.0)
Sets the sub-net mask (user setting).
Normally the default should be selected.
(7) IP address (Default: None)
Sets the IP address (user setting).
The IP address does not need to be set except when the
IP address set method
is
Setup area
.
(8) No. of the other nodes in FA Link (Default: None)
The number of remote nodes (user setting) in the FA Link configuration is displayed.
This cannot be set.
(9) Baud Rate Setting (Default: 10 Mbps (not variable))
Sets the baud rate for FL-net communications. To communicate at 100 Mbps, select
Auto
. The baud rate is
determined by the auto-negotiation function of the connected hub.
(10) Show data
Selects whether data is to be given in decimal or hexadecimal.
(11) Send
Writes to the System Setup Area of the specified Unit.
(12) Receive
Reads the contents of the System Setup Area of the specified Unit to the FL-net Unit Support Software.
(13) OK
Validates the changed settings and closes the window.
When the System Setup Window is next opened, the changed settings will be displayed.
(14) Cancel
Cancels the changes to the settings and closes the window.
When the System Setup Window is next opened, the settings prior to the changes will be displayed.
Note
(1) In order to circulate a token among nodes connected to the network, match the uppermost three
digits of the IP address, the sub-net mask, and the broadcast type to those of the other connected
nodes.
(2) If either
Unit rear rotary SW + node No.
or
Unit rear rotary SW
is set as the IP address setting meth-
od for a CS1W-FLN22 or CJ1W-FLN22, a setting error will occur (HER indicator will light). Set the
IP address setting method to either
192.168.250 + node No.
(default) or
Setup area
.
(3) The baud rate setting is supported by CS1W-FLN22 and CJ1W-FLN22 only. The setting cannot be
made for CS1W-FLN02 or CS1W-FLN12, which always communicate at 10 Mbps.
Summary of Contents for CJ1W-FLN22
Page 2: ......
Page 3: ...CS1W FLN22 100Base TX CJ1W FLN22 100Base TX FL net Units Operation Manual Revised October 2010...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ......
Page 14: ...xiv...
Page 18: ...xviii...
Page 26: ...xxvi Unit Versions of CS CJ series FL net Units 7...
Page 40: ...Precautions Section 1 6 14...
Page 50: ......
Page 88: ...Allocated Words in the DM Area Section 4 4 62...
Page 158: ...Command Response Reference Section 7 5 132...
Page 170: ......
Page 192: ...Inspections Section 10 6 166...
Page 218: ...192 System Configuration Appendix A...
Page 224: ...198 System Configuration Example Appendix B...
Page 270: ...244 FL net Unit Support Software Ver 1 6 Appendix F...
Page 276: ...250 International System of Units Appendix G...