Specifications
Section 1-5
12
Comparison with Previous Models (CS1W-FLN02, CS1W-FLN12)
Comparison between FL-net Unit Support Software
Model
CS1W-FLN22
CJ1W-FLN22
CS1W-FLN02/12
Type
100Base-TX (10Base-T is also possible)
10Base-5 (CS1W-FLN02)
10Base-T (CS1W-FLN12)
Switches/indica-
tors
100M indicator provided
This indicator indicates when baud rate of 100
Mbps is being used.
No 100M indicator
No rotary switch for setting the IP address.
The IP address is set using the CX-FLnet or FL-
net Unit Support Software. Either of the following
two methods can be used to set the IP address.
1. 192.168.250 + node number
2. Setup area
Rotary switch provided on rear of Unit for setting
the IP address. Either of the following four meth-
ods can be used to set the IP address
1. 192.168.250 + node number
2. Rotary switch on rear of Unit.
3. Rotary switch on rear of Unit + node number
4. Setup area
Data link func-
tions
Total capacity: 8,704 words
(Area 1: 512 words, Area 2: 8,192 words)
If the total number of words in Area 1 and Area 2
for a single node exceeds 7,677 words, the data
for the corresponding node will be refreshed over
two scans of the CPU Unit. The data will be split
from the 7,678th word counted from the beginning
of the combined Area 1 and Area 2.
Total capacity: 8,704 words
(Area 1: 512 words, Area 2: 8,192 words)
Data link tables that exceed the following condi-
tions, however, cannot be set.
Number of words in local node setup area (Area 1
and Area 2)
≤
7,677 words.
Number of words in local node setup area (Area 1
and Area 2) + the number of words in setup area
(Area 1 and Area 2) for node with the largest setup
area size (except local node)
≤
7,677 words
The order of the upper and lower byte in the word
data can be swapped for each node when
exchanging data between the data link area in the
PLC and the FL-net.
The data order cannot be changed and is fixed as
shown in the following diagram.
Simple backup
function
Supported.
Not supported.
Support Soft-
ware
CX-FLnet or FL-net Unit Support Software version
1.60 or higher (CS1W-FLN22 and CJ1W-FLN22
settings cannot be made using Ver. 1.51 or lower)
FL-net Unit Support Software Ver. 1.51 or higher
(CS1W-FLN02 and CS1W-FLN12 settings can
also be made using Ver. 1.60 or higher)
Version
CX-FLnet or
FL-net Unit Support Software Ver. 1.60
Ver. 1.51
New setting
function
Set the baud rate.
Set the data link data order.
None (these settings are not available)
Connection with
PLC
Set/monitor other nodes via the FL-net network.
Only the local node can be set or monitored.
Setting file
Setting files saved from Japanese version and
English version are compatible.
No compatibility between setting files saved in the
English version and Japanese version.
MSB
LSB
D15
0
Common memory
PLC memory area
Summary of Contents for CJ1W-FLN22
Page 2: ......
Page 3: ...CS1W FLN22 100Base TX CJ1W FLN22 100Base TX FL net Units Operation Manual Revised October 2010...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ......
Page 14: ...xiv...
Page 18: ...xviii...
Page 26: ...xxvi Unit Versions of CS CJ series FL net Units 7...
Page 40: ...Precautions Section 1 6 14...
Page 50: ......
Page 88: ...Allocated Words in the DM Area Section 4 4 62...
Page 158: ...Command Response Reference Section 7 5 132...
Page 170: ......
Page 192: ...Inspections Section 10 6 166...
Page 218: ...192 System Configuration Appendix A...
Page 224: ...198 System Configuration Example Appendix B...
Page 270: ...244 FL net Unit Support Software Ver 1 6 Appendix F...
Page 276: ...250 International System of Units Appendix G...