Troubleshooting Procedures
Section 10-4
160
Network Relay Errors
SEND(090) or RECV(098)
For network relay errors using SEND(090) or RECV(098), check the path of
the command using the routing tables and the nature of the error using the
response code to eliminate the cause of the error.
10
Command
format error
01
01: Com-
mand too
long
Command data
The command is longer
than the max. permissible
length.
Check the command format
and set the command data
correctly.
Broadcast transmissions
exceeded 1,473 bytes.
02
Command
too short
Command data
The command is shorter
than min. permissible
length.
03
Element-
data mis-
match
Command data
The designated number
of data items differs from
the actual number in the
command data.
Check the number of items
and the data, and make sure
that they agree.
05
Header
parameter
error
Command data
Data for another node on
the same network was
received from the net-
work.
Check the command format
and set the command data
correctly.
An attempt was made to
send response data for a
broadcast address.
Sequential
error
---
An error response was
returned for the instruc-
tion executed at the
remote node.
Check the status of the
remote node.
11
Parameter
error
03
Address
specifica-
tion out of
range
First word
address in com-
mand data
The first word in the com-
mand is in an inaccessi-
ble area.
Set a first word that is in an
accessible area.
The bit number is not 00.
Check the variable area speci-
fied in the results storage area
and set the bit number to 00.
04
Address
range
exceeded
Command data
The address set in the
command is not correct.
Correct the address in the
command data, being sure
that the beginning address
plus the number of elements
does not exceed the accessi-
ble memory.
0B
Response
too long
Command data
The response frame is
too long.
Correct the number of data
elements or other parameters
in the command data for
which the response is being
returned.
0C
0C: Param-
eter error
Parameters in
command data
Parameters are set incor-
rectly in the command
data.
Check the command data and
correct any parameters that
are incorrect.
26
Command
error
05
Servicing in
progress
System load
Execution of the previous
command has not been
completed.
Correct the user application to
reduce the load (traffic) at the
FL-net Unit.
30
Access
control
error
00
EEPROM
access
error
---
The EEPROM device has
deteriorated.
Restart the CPU Unit. If the
error recurs, replace the FL-
net Unit.
Main response
code
Sub-response code
Check point
Probable cause
Remedy
Value
Meaning
Value
Meaning
Summary of Contents for CJ1W-FLN22
Page 2: ......
Page 3: ...CS1W FLN22 100Base TX CJ1W FLN22 100Base TX FL net Units Operation Manual Revised October 2010...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ......
Page 14: ...xiv...
Page 18: ...xviii...
Page 26: ...xxvi Unit Versions of CS CJ series FL net Units 7...
Page 40: ...Precautions Section 1 6 14...
Page 50: ......
Page 88: ...Allocated Words in the DM Area Section 4 4 62...
Page 158: ...Command Response Reference Section 7 5 132...
Page 170: ......
Page 192: ...Inspections Section 10 6 166...
Page 218: ...192 System Configuration Appendix A...
Page 224: ...198 System Configuration Example Appendix B...
Page 270: ...244 FL net Unit Support Software Ver 1 6 Appendix F...
Page 276: ...250 International System of Units Appendix G...