49
CPU Bus Unit System Setup
Section 4-2
CIO Area Allocations
DM Area Allocations
4-2
CPU Bus Unit System Setup
To operate the FL-net Unit as a node on FL-net network, the required parame-
ters must be set in the CPU Bus Unit System Setup, part of the CPU Unit’s
Parameter Areas. If any of the following items apply, then the system parame-
ters must be set.
• The Data Link function is used. The Data Link table is stored in either the
CPU Bus Unit System Setup (PLC built-in method) or the FL-net Unit Sys-
tem Setup (Unit built-in method). (Default: PLC built-in method)
• The startup method is changed. (Default: Automatic participation method)
• Message protocol confirmation is changed. (Default: Confirm)
• The broadcast method is changed. (Default: ***.***.***.255)
• The IP address is set. (Default: 192.168.250 + node number)
• The subnet mask is changed. (Default: 255.255.255.0)
• The baud rate is changed to 100 Mbps. (Default: 10 Mbps)
Newly set parameters go into effect after the FL-net Unit has been restarted
or after the CPU Unit is started again.
The settings are made in the CPU Bus Unit System Setup using the CX-FLnet
or FL-net Unit Support Software.
Note
The CPU Bus Unit System Setup is located in the CPU Unit’s Parameter Area,
and not in I/O Memory; parameters cannot be written using instructions or by
editing I/O Memory. The settings can be made only by using the CX-FLnet or
FL-net Unit Support Software.
Unit No.
(decimal)
Allocated words
Unit No.
(decimal)
Allocated words
0 (0)
CIO 1500 to CIO 1524
8 (8)
CIO 1700 to CIO 1724
1 (1)
CIO 1525 to CIO 1549
9 (9)
CIO 1725 to CIO 1749
2 (2)
CIO 1550 to CIO 1574
A (10)
CIO 1750 to CIO 1774
3 (3)
CIO 1575 to CIO 1599
B (11)
CIO 1775 to CIO 1799
4 (4)
CIO 1600 to CIO 1624
C (12)
CIO 1800 to CIO 1824
5 (5)
CIO 1625 to CIO 1649
D (13)
CIO 1825 to CIO 1849
6 (6)
CIO 1650 to CIO 1674
E (14)
CIO 1850 to CIO 1874
7 (7)
CIO 1675 to CIO 1699
F (15)
CIO 1875 to CIO 1899
Unit No.
(decimal)
Allocated words
Unit No.
(decimal)
Allocated words
0 (0)
D30000 to D30099
8 (8)
D30800 to D30899
1 (1)
D30100 to D30199
9 (9)
D30900 to D30999
2 (2)
D30200 to D30299
A (10)
D31000 to D31099
3 (3)
D30300 to D30399
B (11)
D31100 to D31199
4 (4)
D30400 to D30499
C (12)
D31200 to D31299
5 (5)
D30500 to D30599
D (13)
D31300 to D31399
6 (6)
D30600 to D30699
E (14)
D31400 to D31499
7 (7)
D30700 to D30799
F (15)
D31500 to D31599
Summary of Contents for CJ1W-FLN22
Page 2: ......
Page 3: ...CS1W FLN22 100Base TX CJ1W FLN22 100Base TX FL net Units Operation Manual Revised October 2010...
Page 4: ...iv...
Page 6: ...vi...
Page 10: ......
Page 14: ...xiv...
Page 18: ...xviii...
Page 26: ...xxvi Unit Versions of CS CJ series FL net Units 7...
Page 40: ...Precautions Section 1 6 14...
Page 50: ......
Page 88: ...Allocated Words in the DM Area Section 4 4 62...
Page 158: ...Command Response Reference Section 7 5 132...
Page 170: ......
Page 192: ...Inspections Section 10 6 166...
Page 218: ...192 System Configuration Appendix A...
Page 224: ...198 System Configuration Example Appendix B...
Page 270: ...244 FL net Unit Support Software Ver 1 6 Appendix F...
Page 276: ...250 International System of Units Appendix G...