— 11-4 —
u
Sequence code
Command
: (HS), (AR), ( R )
Conditions
: *, &
l
When a sequence code is added to a command, a program executes the next channel
continuously without selecting a channel externally.
Table 11-2
Sequence code
IPOS output
Execution of the next channel
*: asterisk
Yes
Executes next program continuously after positioning is finished.
& : ampersand
Yes
Stops after positioning, then waits for RUN command.
[Program example]
:CH0
IR5000*
:CH1
IR1000&
Figure 11-4
IR500
*
IR1000&
CH0
PRG0 ~ 5
RUN input
Programmed
Operation
IPOS output
(FW
¹
0)
CH1
0
u
Sequence code change
Conditions
: OE
l
OE seq makes possible to change a currently set sequence code.
[Program example]
:CH0 --------------
Specify an objective channel.
AR9000&
CV300
?OE* --------------
input
ENT
E
*
O
?
:TC0 --------------
Confirm a changed channel.
AR9000* ----------
Sequence code is changed from “&” to “
*
”.
CV3000
: