— 12-31 —
«
«
«
«
WM : Write Mode to EEPROM
Format
: WM data
Data
: 0 or 1
Shipping set
: 0
Default
: 0
l
500 000 times of resetting/deleting parameters to EEPROM are possible as data back-up.
However, frequent resetting/deleting of parameters may exceed the expected life of EEPROM.
“WM” is to select data back-up mode to reduce frequency of parameter resetting/deleting
WM0 : Data back-up valid
WM1 : Data back-up invalid
!
Caution : • When the setting is changed from “WM1” to “WM0”, it takes
approximately 30 seconds for storing all data.
• Do not turn the power off while executing the command.
• If the power is turned off, memory error alarm may be issued.
l
When “SI” is executed, all initialized parameters are stored to EEPROM even “WM” command
is set to invalid.
l
“TS” or “?WM” reports the current setting.
«
«
«
«
ZP
: Factory Use Only
Shipping set
: 1.00
!
Caution : • The parameter is for the automatic tuning function and is set at the
factory.
• Do not change the setting.
• “TS” or “?ZP” command reports the current setting.
«
«
«
«
ZV
: Factory Use Only
Shipping set
: 1.4
!
Caution : • The parameter is for automatic tuning function and to be set at the
factory.
• Do not change the setting.
• “TS” or “?ZP” command reports the current setting.