— 8-12 —
(2)
Observing the Motor operation, press the plus (+) key several times.
[+]
[+]
[+]
[+],[-],[ENT]
,[-],[ENT]
,[-],[ENT]
,[-],[ENT]
333
333
333
333( 222)
( 222)
( 222)
( 222)
STEP1
STEP1
STEP1
STEP1
_VG3
_VG3
_VG3
_VG3
Pressing
,
SHIFT
-
+
-
+
• • •
As the response index decreases, the movement of the Motor is getting crisply.
(3)
Keep pressing the plus (+) key, eventually the Motor starts hunting and stops.
[+]
[+]
[+]
[+],[-],[ENT]
,[-],[ENT]
,[-],[ENT]
,[-],[ENT]
233
233
233
233( 123)
( 123)
( 123)
( 123)
STEP1
STEP1
STEP1
STEP1
_VG5
_VG5
_VG5
_VG5
Pressing
,
SHIFT
-
+
-
+
• • •
(4)
Keep pressing the minus (-) key until the Motor stops hunting and starts moving.
[+],[-],[ENT]
253( 145)
STEP0.1
_VG4
-
+
-
+
• • •
(5)
Set the “VG” value to 80% of displayed “VG” when a hunting is stopped.
4 × 0.8 = 3.2
(6)
Press the space key to change the resolution of “VG” setting value from 1.0 to 0.1.
[+],[-],[ENT]
263( 156)
STEP0.1
_VG4
SP
(7)
Press the minus key till “VG” value reaches to 3.2.
[+],[-],[ENT]
263( 156)
STEP0.1
_VG4
-
+
-
+
• • •
(8)
Press the enter key to store the “VG” value.
263( 156)
STEP0.1
VG3.2
:_
ENT
A colon ( : ) will appear to comfirm the input.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com