— 6-6 —
Table 6-3: Contact Requirements
Contacts
For ESA Type
No-Fuse Breaker
Current Rating 15A
Short-Circuit Breaker
Contact Capacity 15A
Sensitivity 15mA
Magnetic Switch
Contact Capacity 30A
Table 6-4: Inrush Current
Inrush Current (TYP)
Item
AC100v
AC200V
Control Power
7A
14A
Main Power
40A
140A
l
Install a surge killer circuit for magnet switches, relays and solenoids.
l
When replacing the fuse F1 or F2 of the Driver Unit, use the fuse packed with the Driver Unit
when it is shipped.
!
Caution : • Use the R-S terminals when connecting single-phase 200 VAC for the
main power supply. Surge current becomes larger when the R-T
terminals are in use.
• During wiring, be careful not to loose terminal block screws, etc.
!
Danger : Install the plastic protection on TB Terminal Block after wiring. The
terminals on TB will be at high voltage when power is turned on.
Removing the protection and touching terminals may cause extreme
electrical shock.
Note: Refer to “5. Connector Specifications” for the connector wiring.