— 12-20 —
NS
: Notch Filter, Secondary (secondary notch filter frequency)
Format
: NS data
Data
: 0, 10 ~ 500 [Hz] or /AJ (adjust mode)
Shipping set
: 0
Default
: 0
l
NS data sets frequency of secondary notch filter.
l
If “0” is specified, the 2nd stage notch filter will be set to OFF. In such a case the display shows
“SEC.NF.OFF.”
l
If the data other than “0” (i.e., 10 ~ 500) is specified, the frequency sets to data.
l
Command “TS” or “?NS” reports the frequency setting.
l
“NS/AJ” starts adjusting program.
«
«
«
«
NW : Neglect Width
Format
: NW data
Data
: 0 ~ 4
Shipping set
: 2
Default
: 0
l
RUN and HOS are edge-triggered inputs. To protect against multiple inputs due to contact
chattering, the NW parameter sets a timer length to confirm the receipt of that input; when NW
data is specified, the input pulse is detected a specified time after it initially went high (rising
edge).
Timer = data × 2.8 [ms]
l
“TS” or “?NW” command reports the current setting.
OE
: Sequence Option Edit
Format
: OE data
Data
: * or &
Default
: Not omissible
l
OE changes the sequence code of a program already specified in a channel.
l
If this command is entered under the condition where a channel whose sequence code shall be
changed is selected with a CH command, the Driver Unit outputs “?,” and the system waits for a
command to be entered, the sequence code of the program already specified in the channel is
changed into ‘data.’ If OE is entered in the normal stand-by state, an error occurs.
l
“Data” indicates the sequence code. Adding the sequence code enables to execute the
positioning of next channel without selecting channel externally.
* After the positioning is over, “IPOS” signal is output and execute next channel’s
program.
& After the positioning is over, output “IPOS” signal and stops. Then execute the next
channel’s program when “RUN” command is input.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com