— 10-13 —
10.4.3. Input Timing
!
Caution : The following specifies the conditions of pulse acceptance timing.
Besides these conditions, the Motor operation is restricted by the
maximum velocity. Do not input pulses faster than Motor’s maximum
velocity.
(1) When PC is set to “0” (PC0)
Figure 10-8
Min. 600ns
PLSP input: PLS pulses
MNSP input: MNS pulses
ON
OFF
ON
OFF
Min. 600ns
Min. 1µs
MNS Motor
PLS Motor
(2) When PC is set to 1 (PC1)
Figure 10-9
Min. 500ns
Min. 500ns
PLSP input: Direction
MNSP input: Step
ON
OFF
ON
OFF
MNS Motor
PLS Motor
Min. 500ns
Min. 600ns
Min. 600ns
(3) When PC is set to 2~4 (PC2~PC4)
Figure 10-10
Min. 1µs
Min. 5µs
Min. 2µs
PLSP input: øA
MNSP input: øB
ON
OFF
ON
OFF
MNS Motor
PLS Motor
Min. 2µs
Min. 1µs
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com