— 12-27 —
TC
: Tell Channel Program
Format
: TC data
Data
: 0 ~ 15 or /AL
Default
: 0
l
Reports the program contents of a channel specified on
ヤ
data
ユ
.
l
No data is displayed if program is not set to the channel.
l
“TC/AL” command is to scroll all channels with pressing the space key.
TE
: Tell Position Error Counter
Format
: TE/RP
l
Reads the value of the position error counter. The displayed value is between –2 147 483 648
and +2 147 483 647. If it exceeds or lowers below the upper or lower limit, it is changed into the
lower or upper limit with a reversed sign.
l
If an /RP option is added to a TE command, reading is repeated automatically.
l
In automatic reading, a value consisting of up to six figures is read out. If a value consists of
more than six figures, “*******” is displayed.
l
To terminate automatic reading, press the BS key.
l
When only “TE” is entered, the display shows the value at the moment.
«
«
«
«
TL
: Torque Limit Rate
Format
: TL data
Data
: 0 ~ 100 [%]
Shipping set
: 100
Default
: 0
l
Sets the torque limit.
l
The Motor torque will be reduced to a percentage (%) of the maximum torque immediately after
“TL” is input and the Motor torque is controlled not to exceed the limit.
l
“TS” or “?TL” reads the current setting.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com